Back to top
Capsulorhexis Cystotome
Capsulorhexis Cystotome

Capsulorhexis Cystotome

MOQ : 1 Unit

Capsulorhexis Cystotome Specification

  • Function
  • Capsulorhexis (Creation of circular tear in anterior lens capsule)
  • Diameter
  • 0.3 mm - 0.4 mm (depending on gauge)
  • Instruments Type
  • Cystotome
  • Blade Type
  • Bent Needle Tip
  • Finish Type
  • Matte / Satin
  • Disposable Or Reusable
  • Disposable
  • Surface Finish
  • Smooth Polished
  • Instrument
  • Capsulorhexis Cystotome
  • Type
  • Surgical Instrument
  • Material
  • Stainless Steel
  • Condition
  • New
  • Technology
  • Precision Formed Tip
  • Portable
  • Yes
  • Rechargeable
  • No
  • Foldable
  • No
  • Sterilized
  • Yes
  • Waterproof
  • Yes
  • Use Type
  • Ophthalmic Surgery
  • Usage
  • Single Use / Disposable
  • Operating Type
  • Manual
  • Dimension (L*W*H)
  • Standard (customized as per requirement)
  • Weight
  • Lightweight
  • Application
  • Anterior Capsulotomy in Cataract Surgery
  • Features
  • Sharp tip, Ready-to-use, Sterile packed
  • Type Of Equipment
  • Ophthalmic Surgical Instrument
  • Size
  • 23G / 26G (Common variants)
  • Latex Free
  • Yes
  • CE Marked
  • Yes
  • Needle Angle
  • 45 / 90 depending on design
  • Shelf Life
  • 5 years
  • Safety Standard
  • Meets International Medical Standards
  • Sterility Assurance Level
  • SAL 106
  • Packaging Type
  • EO Sterile Blister Pack
  • Compatibility
  • Universal-standard for most ophthalmic surgical kits
  • Color Code
  • As per gauge size
  • Handle Type
  • Ergonomic for controlled manipulation
 

Capsulorhexis Cystotome Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 5000 Units Per Day
  • Delivery Time
  • 7-20 Days
 

About Capsulorhexis Cystotome

We are the leading manufacturers, exporters and suppliers of our highly offered Capsulorhexis Cystotome. It can be used to pick up the anterior capsular flap created by the cystotome needle to complete the capsulorrhexis. The offered cannula is manufactured by our adept professionals using high quality raw material and sophisticated technology a tour well-equipped production house. Our offered Capsulorhexis Cystotome is made available to our clients at affordable prices.

 

Features:

  • High strength
  • Durability
  • Light weight



Ergonomic Design for Precision

The Capsulorhexis Cystotome features a uniquely ergonomic handle that ensures optimal grip and control. This design mitigates hand fatigue and enhances accuracy when creating a circular tear in the anterior lens capsule. The lightweight form factor also facilitates portable use without compromising stability or precision in the operating room.


Sterile Safety and International Standards

Each instrument is EO sterile blister packed, with a sterility assurance level (SAL) of 10. Manufactured to meet rigorous international medical standards and bearing the CE mark, it is guaranteed safe for use. The products latex-free composition eliminates allergen concerns, and its disposable nature upholds infection control protocols during surgical procedures.


Universal Compatibility and Customized Fit

The cystotome is designed to function seamlessly with most standard ophthalmic surgical kits. Offered in common 23G and 26G variants, its color-coded gauge sizes and customizable dimensions ensure suitability for varied surgical preferences. This adaptability allows ophthalmic professionals to select the best instrument for specific patient and procedural requirements.

FAQs of Capsulorhexis Cystotome:


Q: How does the Capsulorhexis Cystotome facilitate controlled capsulotomy during cataract surgery?

A: The instruments sharp bent needle tip and ergonomic handle allow surgeons to create a precise circular tear in the anterior lens capsule. This control ensures uniform incisions and minimizes tissue trauma, which is critical for successful cataract procedures.

Q: What sterility measures are in place for this instrument?

A: Each cystotome is EO sterilized and packaged in a sterile blister pack, providing a sterility assurance level (SAL) of 10. It complies with international medical safety standards, including CE marking, to minimize infection risks during surgery.

Q: When should this cystotome be used in ophthalmic procedures?

A: It is specifically intended for use during the capsulorhexis phase of cataract surgery, where a controlled opening is made in the anterior lens capsule prior to lens extraction or implantation.

Q: Where can the Capsulorhexis Cystotome be incorporated within surgical kits?

A: This instrument boasts universal compatibility and fits seamlessly into most standard ophthalmic surgical kits, making it suitable for use in medical facilities worldwide.

Q: What benefits does the ergonomic handle provide for practitioners?

A: The ergonomic design reduces hand fatigue, improves instrument stability, and allows more precise manipulation, enhancing overall performance and safety during surgery.

Q: What is the process for using this cystotome in surgery?

A: After sterile unpacking, the surgeon uses the manual, ready-to-use cystotome to initiate and guide a precise capsulorhexis. Its sharp tip and smooth surface finish aid in efficient, controlled tissue incision, which is then followed by the remaining steps in cataract removal.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Disposable Cannula Category

Bimanual Irrigation / Aspiration Handpieces

Bimanual Irrigation / Aspiration Handpieces

Minimum Order Quantity : 1 Unit

Operating Type : Manual

Size : Standard

Technology : Other, Bimanual Control

Usage : Ophthalmic Surgery

Foldable : No

Cystotome Cannula

Cystotome Cannula

Minimum Order Quantity : 1 Unit

Operating Type : Manual

Size : 19G, 20G, 21G (custom sizes available)

Technology : Other, Microsurgical

Usage : Single use or reusable (as per model)

Foldable : No

Simcoe I and A Cannula (2 way cannula)

Simcoe I and A Cannula (2 way cannula)

Minimum Order Quantity : 1 Unit

Operating Type : Manual

Size : Various sizes available (common: 22G, 23G)

Technology : Other, Conventional Cannula Technology

Usage : Manual Irrigation and Aspiration during Cataract Surgery

Foldable : No

Simcoe Cannula (Aspiration Port)

Simcoe Cannula (Aspiration Port)

Minimum Order Quantity : 1 Unit

Operating Type : Manual

Size : Various (commonly 23G, 20G)

Technology : Other, Precision Engineered

Usage : Ophthalmic Surgery

Foldable : No